MPA-626: Installation and Operation Manual 15
Microphone Inputs
Frequency Response
100Hz / -3dB(filter) 20kHz ±0.5dB
Distortion
<0.03% 1kHz
Gain Range
40dB
Input Impedance
Common mode rejection
>70dB 1kHz
Headroom
>20dB
-127dB EIN 22Hz-22kHz (150)
Equalisation
HF: ±10dB/5kHz LF: ±10dB/100Hz
Outputs
Auxiliary Outputs
775mV (0dBu) unbalanced (RCA phono sockets), 1output
fixed level, one variable
150 watts rms/4 105watts rms/8 via screw terminals
100V line output
100 volts balanced – 83 min load (120W)
70 volts balanced – 40 min load (120W)
50V line output
Protection
VI Limiting, DC Offset, Thermal & switch-on delay
Cooling
Convection
19 General Specifications
Power input
230V ±5% (115V ±5% available) 40 to 60 Hz
Typical power consumption
160VA
>2k (balanced)
Noise
Speaker Outputs
120 watts rms/2 via screw terminals
70V line output
50 volts balanced – 21 min load (120W)
Fuse rating
T3.15A for 230V supply T6.3A for 115V supply
Fuse type
20mm x 5mm class 3T 250V
Dimensions (cm)
48.26 x 8.80(2U) x 30.00 deep (+ connectors)
Weight (kg)
8.70kg net
20 Factory Default Jumper Settings
JUMPER FUNCTION DEFAULT SETTING
J1
Mic 1 phantom power OFF
J2
Mic 2 phantom power OFF
J3
Mic 2 access attenuates music OFF
J4
Mic 1 access attenuates music OFF
J5
Mic 1+2 auto voice over ON
J6
Mic 1+2 level off access attenuation see J3+J4 30dB
J7
Mic 2 access triggers chime OFF
J8
Mic 1 access triggers chime OFF
J9
Mic 1 access mutes facility input OFF
J10+J11
High pass filter frequency 20 or 70 Hz 20 Hz
J12
Disable/enable front panel volume control ENABLE
J13
L6 priority release time 3s, 6s, 12s 6s
This product conforms to the following European EMC Standards:
BS EN 55103-1:1997
BS EN 55103-2:1997
This product has been tested for use in commercial and light industrial environments. If the equipment is
used in controlled EMC environments, the urban outdoors, heavy industrial environments or close to
railways, transmitters, overhead power lines etc. the performance of the unit may be degraded.
The product conforms to the following European electrical safety standard.
BS EN 60065:1998
11-07-02 V4